Box Compression Test Formula and the McKee Equation
By Lim Xu, Export Manager
The box compression test formula most packaging engineers use is the simplified McKee equation: BCT = 5.87 × ECT × √(h × Z). It estimates how much top to bottom load an empty corrugated box can take from the edge crush strength of its board, the board caliper and the box perimeter.
What is the box compression test formula?
Box compression strength (BCT) is the peak load a box carries before it fails in a compression test such as ASTM D642 or TAPPI T 804. A formula lets you estimate that value from board data before any boxes are made.
The standard reference is the McKee formula, published by McKee, Gander and Wachuta in 1963 as a compression strength formula for corrugated boxes. It links box strength to the edgewise compression strength of the combined board, its bending stiffness and the box perimeter.
The full equation is too involved for everyday use, so most people use the simplified form. It replaces bending stiffness with board caliper, which any lab can measure quickly.
The McKee equation term by term
The full McKee equation, with the constants fitted to the 1963 data, is BCT = 2.028 × ECT^0.746 × (√(DMD × DCD))^0.254 × Z^0.492. The simplified version is BCT = 5.87 × ECT × √(h × Z).
- BCT is the predicted box compression strength, in pounds-force.
- ECT is the edge crush strength of the combined board, in lb/in, measured on a short column such as TAPPI T 839.
- DMD and DCD are the bending stiffnesses of the board in the machine and cross directions.
- h is the board caliper, in inches.
- Z is the box perimeter, 2 × (length + width), in inches.
The constant 5.87 only works with these inch-pound units. If your ECT is in kN/m and your dimensions are in millimetres, convert to lb/in and inches first, then convert the result back.
McKee assumed a square footprint, and the formula expects panels that bulge before they fail. The Georgia Tech guidance gives a depth of at least Z/7 for this to hold; shorter boxes behave differently.
Questions about a model or a test? Email Amy Zhao, Export Manager, at info@packagingtestequipment.com.
Worked example from ECT to BCT
The numbers below are hypothetical and only show the arithmetic. Take a regular slotted box with an 18 in × 12 in footprint, made from board with an ECT of 40 lb/in and a caliper of 0.160 in.
- Perimeter: Z = 2 × (18 + 12) = 60 in.
- Caliper times perimeter: 0.160 × 60 = 9.6, and √9.6 ≈ 3.0984.
- BCT = 5.87 × 40 × 3.0984 ≈ 727.5 lbf.
- Depth check: Z/7 = 60/7 ≈ 8.6 in, so the box should be at least that deep.
In SI units, 727.5 lbf is about 3.24 kN, using the NIST factor of 4.448 222 N per lbf. The ECT of 40 lb/in is about 7.0 kN/m, using 175.126 8 N/m per lbf/in.
Round only at the end. Rounding ECT or caliper early can shift the result noticeably, and a lower rounded value is the safer direction for a design estimate.
Safety factors for stacking, humidity and time
A McKee result is a short term strength at standard conditions. A box in a warehouse stack sees a constant load for days or months, often in damp or changing air.
Research from the US Forest Products Laboratory (FPL) notes that bottom boxes in long term storage can fail at loads far below the strength from a dynamic compression test. Paper is sensitive to moisture, so high or cycling humidity makes this worse.
That is why designers divide the predicted or measured BCT by a safety factor before setting a stacking load. The size of that factor depends on storage time, humidity, pallet pattern and handling, so take it from your own test data or your customer's specification rather than a generic table.
For high value or long storage shipments, a stacking life test at one fixed load does not adequately predict a safe load for a fixed storage time. The FPL study tested corrugated fiberboard specimens, not whole boxes, and used several load levels to find the load with a 5% probability of failure for a given storage time.
If you need to compare boxes on real data, our KY-2 carton compression tester tests whole cartons.
You can see it alongside our burst testers in the burst and compression testers range.
When to measure BCT instead of calculating it
The simplified McKee equation is quick but not very accurate. Georgia Tech recommends the full equation with measured bending stiffness, or fitting the constants to a set of your own similar boxes, when accuracy matters.
Measure BCT on real boxes in these cases:
- The box has hand holes, vents or other cutouts, where the McKee formula alone does not estimate strength well.
- The contents or inner packing share the load.
- The box style is not a regular slotted container, or the footprint is far from square.
- You are qualifying a new board grade or supplier.
How you test also changes the number. ASTM D642 notes that fixed platen machines generally make corrugated boxes fail at their strongest point, while swivel platen machines make them fail at their weakest point. State the platen type in the report so results can be compared.
Frequently asked questions
Is BCT the same as ECT?
No. ECT is measured on a small strip of combined board loaded on its edge. BCT is measured on a whole box. The McKee equation is the usual bridge between the two.
Can a box be compression tested in other directions than top to bottom?
Yes. ASTM D642 covers loads applied to the faces of a container, to diagonally opposite edges or to corners, and notes that edge-to-edge and corner-to-corner tests need a fixed head compression machine. TAPPI T 804 lets you test top to bottom, end to end or side to side, in the direction that matches how the box is used.
Talk to our factory team
We sell direct from our factory, so you work directly with our factory team. Questions about a model or a test? Email Amy Zhao, Export Manager, at info@packagingtestequipment.com.
Related articles
- Pressure Decay Leak Test for Packages and Rigid ContainersA pressure decay leak test pressurizes a package and watches for a drop during the hold. See how it differs from vacuum decay and how limits are set.
- Bursting Strength Tester Calibration and What Foils Can CheckBursting strength tester calibration under ISO 2758 and ISO 2759 covers pumping rate, peak pressure and clamping. See why foils check function only.
- Box Compression Test Standards ASTM D642 ISO 12048 and TAPPI T 804Compare the main box compression test standards, ASTM D642, ISO 12048 and TAPPI T 804, by scope, contents, orientation, speed and what to report.