Pouch Burst Test for Flexible and Medical Packaging
By Lim Xu, Export Manager
A pouch burst test pumps air into a sealed package and raises the pressure until the package fails. ASTM F1140 runs it with the pouch free to inflate, and ASTM F2054 holds the pouch between restraining plates so the seal takes the load more evenly. Both give a fast check of how a package handles a pressure difference, not the peel force that ASTM F88 measures.
What a pouch burst test measures
ASTM F1140 covers the ability of packages to withstand internal pressurization. Its burst test raises the internal pressure until the package fails. The standard presents it as a rapid way to see how packages tend to fail under a pressure differential, such as during sterilization or transport.
Manufacturers use these tests to check packages quickly during production and at different stages of the package life cycle. The result is the pressure at failure, and restrained tests also show where the seal opened.
It is not the same as the peel test in ASTM F88, which pulls apart a strip cut through the seal. F1140 notes that its results do not necessarily correlate with seal strength measured to F88.
Unrestrained and restrained burst tests
The difference between the two standards is the restraining plates. Everything else in the test works in a similar way.
Unrestrained test under ASTM F1140
In an unrestrained test the pouch inflates freely. ASTM F2054 points out that the stress is then highest at the middle of the pouch, where it reaches its largest diameter. Stress is not spread evenly along the seal, so an unrestrained test may not find the weakest part of the seal.
That makes F1140 a test of the package's general ability to take pressure. It suits quick checks of how a package takes pressure during process work and in the life cycle stages above.
Restrained plate test under ASTM F2054
ASTM F2054 places the pouch between restraining plates while it is pressurized. The plates keep the package dimensions stable, so stress is applied more evenly around the perimeter, where the seals sit.
This gives a better chance of finding the weakest area of the seal and measures the pressure needed to burst it open. The method applies only to flexible packages with seals around the perimeter, and it is aimed in particular at peelable seals.
F2054 also has limits. It cannot measure seal uniformity, overall package integrity or the burst strength of the areas that touch the plates. The standard advises caution where users design and build their own restraining plate fixtures.
Burst vs creep vs creep-to-failure
F1140 describes a second mode. The creep test holds a specified pressure for a specified time, or until the package fails.
Used with a fixed time, creep gives a pass or fail result at a chosen pressure. Held until the package opens, it becomes creep-to-failure, and the result is the time the package lasted at that pressure.
Burst finds the ceiling, while creep tells you whether a pouch can sit at a lower pressure for a set time. One practical order is to run burst first, then choose a creep pressure below the burst results for the same package design.
Our MFY-02A positive pressure micro-leak and seal strength tester pressurizes packages from the inside. Ask us whether it suits your pouch and test.
Questions about a model or a test? Email Amy Zhao, Export Manager, at info@packagingtestequipment.com.
Where burst testing fits next to peel and leak tests
Burst testing does not replace a peel test. F2054 notes that its results may not correlate with F1140 or F88, and it calls for other methods when overall integrity, seal uniformity or opening function matter.
ASTM F88 measures the force to separate a strip containing the seal and identifies how the specimen failed. Lower seal strength specifications typically give assurance of package closure, and upper ones typically keep a peelable seal openable by the user.
Leak tests answer a different question, whether the package has a hole or channel. Our guide to the bubble leak test covers two common methods. FDA lists ISO 11607-1 and ISO 11607-2 among the publications relevant to ASTM F1140 for medical devices.
How to read the burst pressure and failure location
In a restrained test, F2054 expects the burst to occur in one or more areas of the seal. Note where the pouch opened each time, as well as the pressure. A pouch that keeps opening at the same spot may point to a local seal problem.
Compare results only between identical setups. F1140 lists package size, material, seal configuration, test equipment, the rate of air flow into the package, sensitivity to pressure drop and the position of the package. F2054 adds the rigidity of the plates and the distance between them.
Porous barrier materials need care. F2054 notes that a porous pouch may fail to reach a pressure high enough to burst the seals because the air flow is not sufficient.
Frequently asked questions
Can I run a burst test on a pouch with product inside?
Yes, if you keep the setup the same and record it. The standards describe pressurizing the package itself, and the product changes the free volume and how the pouch inflates. Treat the setup as one more test parameter and record it with the result.
Is a higher burst pressure always better?
Not necessarily. Burst results do not necessarily correlate with peel strength. F88 notes that upper seal strength limits are typically used so that a user can open a peelable design. For a peelable pouch, set a minimum burst pressure and check opening force separately with a peel test.
Talk to our factory team
We sell direct from our factory, so you work directly with our factory team. Questions about a model or a test? Email Amy Zhao, Export Manager, at info@packagingtestequipment.com.
Related articles
- Bursting Strength Tester Calibration and What Foils Can CheckBursting strength tester calibration under ISO 2758 and ISO 2759 covers pumping rate, peak pressure and clamping. See why foils check function only.
- Tensile Strength of Paper and How to Test It under ISO 1924Tensile strength of paper is the peak force per unit width before a strip breaks. See kN/m and tensile index units and ISO 1924-2 test setup.
- Flexible Packaging Testing Equipment for a QC LabFlexible packaging testing equipment for a QC lab usually covers seal integrity, heat seal prep, seal strength, film COF, dart impact and thickness checks.
- FedEx Packaging Test Standards for Parcel ShippersWhat FedEx lists for small-parcel tests, and which of those checks map to carton compression equipment on this site. No unsold drop testers.