Tap Density vs Bulk Density and the Hausner Ratio
By Lim Xu, Export Manager
Tap density vs bulk density is a comparison of how a powder sits when it is poured, and how tightly it packs after it has been tapped. The gap between those two values is used to judge flow, through the Hausner ratio and the Carr index.
Bulk density and tapped density defined
Bulk density, sometimes called apparent or poured density, is the mass of a powder divided by the volume it occupies after it is filled into a vessel without being compacted. It includes the voids between particles.
Tapped density, or tap density, is the mass divided by the volume after the vessel has been tapped a set number of times, or until the volume stops falling. The same sample is usually used for both readings.
USP <616> is the general chapter on bulk density and tapped density of powders. European Pharmacopoeia 2.9.34 and ISO 3953 are other named tapped-density methods, the latter often used for metal powders. ISO 787-11 is a tapped-density method used for pigments and extenders. Use the method your specification names.
How a tapped density test is run
A weighed sample is placed in a graduated cylinder, or in the cup the method requires, and the unsettled volume is read as the bulk volume. The cylinder is then tapped, and the volume is read again.
The tester has to control the drop height, the number of taps and the frequency, because those settings change how far the powder settles. If you change the cylinder or the fill mass, start a new comparison; do not mix volumes from two fills.
Our tap density and angle of repose tester is the instrument we offer for this work. Whether a given setup matches the pharmacopeia or ISO method you follow is something to confirm with us first.
Method 1 and Method 2 drop heights
USP <616> describes more than one apparatus arrangement, often referred to as different methods, with different drop heights. Check the drop heights in the official chapter text.
Use the drop height stated in the method text you work to. This article does not quote those values. If you need help matching an instrument setting to a named method, please confirm with us.
Number of taps
The number of taps, or the rule for stopping when the volume becomes constant, also comes from the method. Some texts fix a count. Others tell you to keep tapping until the volume no longer changes by a set amount.
Write the count, or the endpoint rule, in the report next to the two densities. A tapped density without a tap count cannot be compared with a later lot.
Hausner ratio and Carr index formulas
The Hausner ratio is the tapped density divided by the bulk density. A value close to 1 means the powder packed almost as tightly when it was poured as it did after tapping.
The Carr index, also called the compressibility index, is the difference between tapped and bulk density, divided by the tapped density, then expressed as a percentage. It uses the same two measurements as the Hausner ratio.
USP <1174> is the general chapter on powder flow, and it is the chapter laboratories usually point to when they discuss these two indexes. This article does not include a flow-grade table. Use the limits in the method or the specification you follow.
Tap density testers sit with our other instruments for pharmaceutical work in the pharmaceutical packaging testers collection.
Questions about a model or a test? Email Amy Zhao, Export Manager, at info@packagingtestequipment.com.
What the numbers say about powder flow
A powder that settles a lot when it is tapped usually flows less freely than one whose bulk and tapped volumes are close. That is why the Hausner ratio and the Carr index are used as a first look at flow.
They are not a complete flow study. Particle size, moisture, shape and the way the hopper is designed all matter. A powder can look acceptable on these indexes and still hang in a bin, or the reverse.
Treat the numbers as a comparison within one material and one method. Do not move a limit from a metal powder tested to ISO 3953 onto a pharmaceutical powder tested to USP <616> without a fresh study.
Angle of repose as a second check
The angle of repose is the angle a powder pile makes with the horizontal after it has been poured or drained. A steeper angle often goes with poorer flow, but the result depends on how the pile was formed.
Many labs run angle of repose next to tapped density, because the two checks are quick and use the same sample types. USP <1174> discusses several flow methods, including this one. Report the funnel, the drop height and the way the angle was read, or the result will not travel.
If the two checks disagree, look at moisture and particle size first. A slightly damp powder can stand in a steep pile and still settle under tapping.
Frequently asked questions
Is tap density the same as bulk density?
No. Bulk density is the poured or unsettled value. Tap density is the value after a specified tapping program. The difference between them is what the Hausner ratio and the Carr index use.
Can I use a Hausner ratio table from one pharmacopeia on data from another method?
Only if the vessel, drop height and tap count match. If they do not, the same powder can give a different ratio. Keep the table with the method that produced the data.
What should I send with a request for a quotation?
Tell us the powder type, the method you follow, and whether you also need angle of repose. We can then say which setup to consider and send you a quotation.
Talk to our factory team
We sell direct from our factory, so you work directly with our factory team. Questions about a model or a test? Email Amy Zhao, Export Manager, at info@packagingtestequipment.com.
Related articles
- Needle Penetration Force Test for Hypodermic and Pen NeedlesA needle penetration force test records the force as a hypodermic or pen needle pierces a test film. See how to read the peak and the drag on the curve.
- Ink Rub Test for Printed Cartons and Flexible PacksAn ink rub test rubs a printed carton, label or film under a set load and checks scuff. See dry and wet runs, and how the result is rated.
- Bursting Strength Tester HS Code by CountryHow a bursting strength tester moves from HS subheading 9024.80 to national tariff lines, how binding rulings work, and what paperwork customs needs.
- FedEx Packaging Test Standards for Parcel ShippersWhat FedEx lists for small-parcel tests, and which of those checks map to carton compression equipment on this site. No unsold drop testers.