WVTR Units and How to Convert g/m2/day and g/100 in2/day
By Lim Xu, Export Manager
WVTR units are a mass of water vapor per area per time, usually g/(m²·day) or g/100 in²/day. To convert, multiply a g/100 in²/day value by 15.5 to get g/(m²·day). Multiply by 0.064516 to go back.
The units WVTR is reported in
Every WVTR unit has three parts: a mass, an area and a time. ISO 2528 states its result in g/(m²·d), and ASTM F1249 gives the range of its interlaboratory study in g/(m²·day).
A PNNL report on water permeation notes that mass is usually in grams, area in m² or 100 in², and time in days. Check the area unit first whenever you compare two datasheets.
ASTM E96 treats inch-pound and SI values as separate standards. Derived results can still be converted with the factors in its conversion table. That table pairs g/(h·m²) with grains/(h·ft²), and E96 notes that these units are commonly used in construction.
Converting between metric and inch-pound units
The area factor does all the work, because the gram and the day stay the same. NIST SP 811 lists one square inch as 6.4516 × 10⁻⁴ m², so 100 in² is 0.064516 m².
Dividing the same mass by a smaller area gives a larger number. One g/100 in²/day is 1 ÷ 0.064516 = 15.500031 g/(m²·day), and the PNNL report rounds this to 15.500.
The table below collects the factors you are most likely to need for WVTR.
| Convert from | Into | Multiply by |
|---|---|---|
| g/100 in²/day | g/(m²·day) | 15.500031 |
| g/(m²·day) | g/100 in²/day | 0.064516 |
| grains/(h·ft²) | g/(h·m²) | 0.697 |
| g/(h·m²) | g/(m²·day) | 24 |
As a worked example, a hypothetical film at 0.30 g/100 in²/day gives 0.30 × 15.500031 = 4.6500 g/(m²·day). Round the converted value so its rounding error is no larger than that of the original value (NIST SP 811 B.7.2). The value 0.30 could come from anything between 0.295 and 0.305, about ±1.7%, so 4.7 (about ±1.1%) keeps what 0.30 says. Rounding to 5 would lose it.
Questions about a model or a test? Email Amy Zhao, Export Manager, at info@packagingtestequipment.com.
Why test temperature and humidity belong next to the number
A unit conversion changes the unit, not the test. E96 leaves the test conditions to the user, but they must be reported with the results in every case.
E96 also cautions that results from one set of conditions do not tell you what the same material would give under another. The PNNL report adds that the measuring temperature should be given, because the rate is exponential in the inverse of absolute temperature.
When you convert a supplier value, carry the method, temperature and both humidities across with it. Our guide on how to measure WVTR lists the other fields a WVTR report should include.
If you plan to run WVTR tests in house, ask us about the WTC-303H water vapor transmission rate tester on this site. Tell us your materials and test conditions, and we will reply on whether it fits.
WVTR and OTR units side by side
ASTM D3985 reports oxygen transmission rate (OTR) in cc/(m²·day) and treats SI values as standard. OTR is a volume of oxygen gas per area per time, while WVTR is a mass of water vapor.
The area conversion is identical, so cc/100 in²/day times 15.5 gives cc/(m²·day). There is no factor that turns an OTR value into a WVTR value, because the two describe different gases measured in different quantities.
The two methods also share a structure. D3985 provides OTR, permeance and an oxygen permeability coefficient for homogeneous materials, just as F1249 does for water vapor.
Frequently asked questions
Is g/m2/24 h the same as g/m2/day?
Yes. NIST SP 811 lists one day as 86,400 s, which is exactly 24 h. Both labels describe the same unit, so no conversion is needed.
Can I convert WVTR to perms?
Not with an area factor alone. A perm is a unit of permeance, which also divides by the vapor pressure difference, so you need the test temperature and both humidities. E96 lists transmission and permeance as separate groups in its conversion table.
Is MVTR the same as WVTR?
Yes. MVTR and WVTR are two names for the same quantity. The PNNL report says the moisture vapor transmission rate (MVTR) is also called WVTR and uses the same mass per area per time units.
Talk to our factory team
We sell direct from our factory, so you work directly with our factory team. Questions about a model or a test? Email Amy Zhao, Export Manager, at info@packagingtestequipment.com.
Related articles
- How to Measure Water Vapor Transmission Rate of Packaging FilmHow to measure water vapor transmission rate of film: cup, infrared and electrolytic methods, the conditions that matter and a worked WVTR calculation.
- Water Vapor Permeability vs WVTR and Permeance ExplainedWater vapor permeability is permeance times thickness. See how it differs from WVTR, the formula ASTM E96 uses and a worked conversion with clear units.
- Bursting Strength Tester HS Code by CountryHow a bursting strength tester moves from HS subheading 9024.80 to national tariff lines, how binding rulings work, and what paperwork customs needs.
- FedEx Packaging Test Standards for Parcel ShippersWhat FedEx lists for small-parcel tests, and which of those checks map to carton compression equipment on this site. No unsold drop testers.